If you’ve ever worked in industries where compressed air is the backbone of daily operations—think food and beverage manufacturing, pharmaceutical production, automotive assembly, or even the energy sector—you’ve likely encountered All Air Preparation Units (APUs). As a supplier of these critical systems, I get at least one question a week that goes something like: “Do these units even work when the temperature drops below freezing? Our plant is in [insert generic cold-climate location here], and we can’t afford downtime when the weather turns.” It’s a fair question, and one that comes with a layered answer—rooted in how APUs work, the unique challenges of cold climates, and the small, often overlooked design choices that make the difference between a unit that functions and one that fails when the mercury plummets. Let’s break this down, based on what I’ve seen in 12 years of supplying APUs to plants across North America, Europe, and parts of Scandinavia. All Air Preparation Units

First, let’s recap what an Air Preparation Unit does, because that context is non-negotiable. APUs are a collection of components that clean, dry, and regulate compressed air before it reaches end-use tools, machinery, or processes. Their core job is to remove contaminants that would otherwise damage equipment: water vapor (from atmospheric air pulled into compressors), oil aerosols, solid particulates like rust or dust, and even microbes for sensitive industries like pharma. The key components most APUs include are a primary filter for particulates, a coalescing filter for oil, a refrigerant dryer or desiccant dryer for moisture, and a pressure regulator to keep air at a consistent psi. Each of these parts operates within a specific temperature range—and that’s where cold climates start to cause headaches.
I learned this lesson early on, in 2011, when I worked with a food processing plant in northern Minnesota that had installed a standard off-the-shelf APU ahead of our first brutal winter. That January, temperatures dropped to -22°F (-30°C) for 10 straight days. Within a week, their production line’s blowout nozzles started sputtering, their packaging machines jammed, and the plant’s maintenance team traced the issue straight back to the APU. The refrigerant dryer in their unit was built to operate at a minimum ambient temperature of 33°F (0°C); below that, the refrigerant lines inside the dryer iced over. Not just a thin layer of frost—solid blockage that stopped air flow entirely. The plant lost $45,000 in downtime that week, and they called me the next day to fix it. That experience drove home a truth I still carry: not all APUs are created equal for cold climates.
So why do standard APUs fail in cold weather? Let’s talk through each component’s vulnerabilities, starting with dryers, because moisture is the biggest culprit. Refrigerant dryers are the most common type in mid-sized to large plants, because they’re energy-efficient and low-maintenance. They work by cooling compressed air to around 38°F (3°C), which condenses water vapor into liquid that’s then drained away. The problem is that if the ambient temperature around the dryer drops too low, the cold seeps into the dryer’s heat exchanger. Even if the compressed air inside is warm enough, the outer lines and drainage ports can drop below freezing, turning that condensed water into ice. Most standard APUs have drainage ports that are small, plastic, and uninsulated—perfect for a mild fall day, but useless when temps are low enough to turn a drop of water into a block of ice in an hour. That’s exactly what happened in Minnesota: the 1/4-inch plastic drain froze solid, so the dryer couldn’t remove water, which then traveled through the system and froze in smaller lines and tools.
What about desiccant dryers, the other main type? These use a porous material (desiccant, like silica gel or aluminum oxide) to absorb water vapor from compressed air, and they’re designed to handle lower pressure dew points than refrigerant dryers. But desiccant dryers have their own cold-climate pitfalls, too. If a desiccant unit isn’t properly insulated or if its purge air system is undersized, the desiccant can absorb moisture from the surrounding ambient air when it’s cold, reducing its ability to dry the compressed air. I saw this happen at a chemical plant in northern Sweden a few years ago. They had a desiccant APU installed in an unheated utility room, and over a harsh winter, the desiccant’s efficiency dropped by 30%, leading to corrosion in their precision valve equipment. The issue wasn’t the dryer itself—it was that the unit’s purge air heater had been sized for a plant in southern Germany, not the -15°F (-26°C) temps they saw in Sweden.
Particulate and coalescing filters, the other core APU components, also struggle in cold weather, though less dramatically. Standard filter housings are made of uncoated steel or thin aluminum, which can condense or hold ice if the unit isn’t properly heated. Solid particulates in the compressed air can also become brittle in cold temps, but that’s a minor issue compared to ice buildup. The pressure regulator, which is usually made of plastic and metal, can seize if the small gaps between its moving parts get clogged with ice. I once had a client in Alberta tell me their entire automated assembly line shut down for three hours because the APU’s pressure regulator froze mid-shift—all because the unit was located in an uninsulated corner of the plant. That’s a preventable issue, but only if the APU is designed for cold climates.
Now, the big question: do All Air Preparation Units work in cold climates? The short answer is: only if they’re specifically engineered for cold climates. Off-the-shelf, one-size-fits-all APUs will fail in temperatures below 32°F (0°C), often catastrophically. But cold-climate-specific APUs? I’ve had units running flawlessly in -40°F (-40°C) for years, no downtime, no ice buildup. Here’s what makes a good cold-climate APU different from a standard one, based on the design choices we integrate into every unit we supply.
First, insulation and trace heating. Not the flimsy foam insulation you’d wrap around a pipe, either—closed-cell, high-density insulation that’s sealed to prevent moisture from getting in, paired with self-regulating trace heating cables. These cables only generate heat when the temperature drops below a set point (usually 40°F / 4°C), so they don’t waste energy when it’s mild. We insulate every line, every drain port, and even the outer housing of the APU, not just the key components. The drain ports on our cold-climate units are also larger—1/2 inch, minimum—and made of brass, not plastic, so they’re less prone to cracking if ice does build up temporarily, and the trace heating keeps them from freezing solid.
Second, dryer design tailored for cold temps. For refrigerant dryers used in moderate cold (down to -10°F / -23°C), we adjust the refrigerant charge and add a small internal heating element in the heat exchanger to keep temperatures consistent, even when ambient temps drop. For extreme cold (below -10°F), we switch to desiccant dryers with oversized purge air heaters and insulated desiccant beds. We also add a freeze protection bypass valve that stops air flow through the dryer if temperatures drop too low, redirecting it through a heated bypass line to prevent ice buildup. That’s a feature we don’t include on standard APUs, and it’s a game-changer for plants that see sudden temperature swings.
Third, housing location and integration with the plant’s heating system. A lot of plants make the mistake of sticking APUs in unheated spaces—outside, in unused utility corners, in garages. We advise clients to either install cold-climate APUs in heated indoor areas (even if it’s a small, dedicated utility room) or, if that’s not possible, add a small, thermostatically controlled heater to the APU’s housing. The heater only kicks on when the ambient temp in the housing drops below 35°F (2°C), so it’s energy-efficient but provides the consistent heat the unit needs. The Minnesota plant I talked about earlier? When they called me back after fixing their 2011 issue, we didn’t just replace their APU—we added a 500-watt thermostatically controlled heater and insulated the entire housing, and they haven’t had a cold-related downtime issue in 12 years.
Wait, but what about plants that operate outdoors in extremely cold regions, like mining sites in northern Canada or oil and gas operations in Siberia? I’ve supplied APUs to a mine in Nunavut that runs 24/7 at -35°F (-37°C) year-round. Those units have extra features: weather-sealed, reinforced steel housings, dual trace heating systems, and redundant freeze protection valves. We also test every cold-climate APU we build in our in-house climate chamber, where we can simulate temps as low as -50°F (-46°C) to make sure the unit holds up before it ships. There’s no guesswork here—we’ve had too many clients learn the hard way that off-the-shelf doesn’t work for Arctic conditions.
Another common misconception: people think that heating the entire plant will keep the APU from freezing. That’s partially true, but it’s not enough. I worked with a food plant in Wisconsin that heats its entire production facility to 68°F (20°C), but its APU is located in a loading dock that’s not well-sealed. When the loading dock door opens multiple times a day to receive raw materials, cold air rushes in, dropping the APU’s ambient temp to 28°F (-2°C) for short periods. Even that small drop was enough to make the APU’s drain port freeze. The fix wasn’t heating the whole dock—it was adding a small heater and trace heating to the APU itself, which cost a fraction of what expanding the dock’s insulation would have.
Of course, proper maintenance matters too, regardless of the APU type. I always tell clients in cold climates to do a weekly check of the APU’s temperature gauges and drain function, especially during the first cold snap of the year. A small amount of ice buildup in the drain line can be melted with a heat gun, but if left untreated, it can turn into a major blockage over a few weeks. We also recommend changing the filter elements every 6 months (more often in dusty or high-moisture environments) because clogged filters can restrict air flow and lead to temperature drops inside the unit, even in cold temps.
Let’s circle back to that Minnesota plant. After their 2011 failure, they invested in a cold-climate-specific APU from us, trained their maintenance team to check the drain lines monthly, and added a backup APU for their most critical production line. Last winter, they had a stretch of -25°F (-32°C) temps for 14 days straight, and the APU ran perfectly. No jams, no downtime, no lost revenue. That’s the proof, right there. A standard APU would have failed, but a purpose-built cold-climate APU is a reliable part of their operations, even in harsh conditions.
I’ve also seen the opposite: plants in mild climates that overbuy cold-climate APUs. That’s a waste of money, because the extra insulation and heating elements add upfront cost. But for anyone operating in regions where winter temps drop below 32°F (0°C), or where unheated utility spaces are a reality, cold-climate APUs are non-negotiable. It’s not that All Air Preparation Units can’t work in cold climates—it’s that you need the right All Air Preparation Unit for the climate you’re in.

At the end of the day, compressed air systems are only as good as the components that prepare that air for use. When cold weather hits, even a tiny flaw in design can turn a reliable APU into a costly downtime machine. We’ve built our business over the last 12 years by learning from those mistakes (both ours and our clients’) and engineering APUs that work in every climate, from the mildest coastal regions to the harshest Arctic winters. If you’re running a plant in a cold climate, and you’re tired of dealing with frozen lines, clogged filters, and unplanned downtime, we can help. We can walk you through the right APU for your specific temps, space, and operation, and provide a customized solution that keeps your compressed air system running year-round. To discuss your needs and find the perfect Air Preparation Unit for your cold-climate operations, feel free to connect with our team to arrange a consultation.
Pneumatic Accessories References
- Compressed Air and Gas Institute. (2020). Cold Climate Operation of Compressed Air Preparation Systems. CAGI Technical Bulletin 102.
- Pneumatic Systems Association. (2021). Best Practices for Air Preparation Unit Design in Subzero Temperatures. PSA Industry Report 47.
- International Organization for Standardization. (2019). ISO 10120: Compressed Air Dryers—Specification and Testing.
- U.S. Department of Energy. (2018). Energy Efficiency Guidelines for Industrial Compressed Air Systems in Cold Regions. DOE Industrial Technology Program.
Hangzhou Evershine Pneumatic Import & Export Co., Ltd.
Hangzhou Evershine Pneumatic Import & Export Co., Ltd. is one of the most professional all air preparation units manufacturers and suppliers in China, featured by high quality pneumatic components. Please rest assured to wholesale bulk durable all air preparation units from our factory. Welcome to contact us for custom service and OEM service.
Address: Hengkun Smart Industrial Park, No.176, Golf Road, Yinhu Street, Fuyang District, Hangzhou City, Zhejiang Province, China 311400
E-mail: Felix@waalpc.com
WebSite: https://www.evspneu.com/