If you’ve ever worked in industries that demand ballistic protection—from government facilities to high-value retail locations or private residential properties—chances are you’ve encountered EN 1063 bulletproof glass. As a supplier specializing in this exact standard, I get a lot of questions from installers, project managers, and building owners: “Is EN 1063 glass maintenance-free? Do I need to do anything extra to keep it working as intended?” The short answer is no, it isn’t maintenance-free. But the good news is that EN 1063 glass’s maintenance requirements are specific, straightforward, and designed to preserve the ballistic performance that makes the standard so widely trusted across Europe and beyond. Bulletproof Glass for En1063 Standard

First, let’s ground this in what EN 1063 actually is, because context matters. EN 1063 is the European standard that classifies ballistic resistance for glazing used in protective applications. It categorizes glass into grades BR1 to BR7, each tested to withstand a specific type and caliber of ammunition, from 9mm handguns (BR1) up to .30-06 armor-piercing rounds (BR7). The glass itself is a laminated composite: multiple layers of tempered or annealed glass bonded together with polyvinyl butyral (PVB) or another interlayer, engineered to stop projectiles from penetrating. That interlayer is the unsung hero here—its integrity is what keeps the glass from shattering into dangerous shards and prevents rounds from passing through. So almost every maintenance step ties back to protecting that interlayer and the structural bond between layers.
A common mistake I see new customers make is treating EN 1063 glass like regular float glass. You can use any household glass cleaner, wipe it with a rough cloth, or ignore minor scratches, and that works for everyday windows. But ballistic glass is not the same. Let’s break down the non-negotiable maintenance steps, and the why behind each.
First, cleaning. Regular cleaning is required, but it has to be gentle and specific. Hard, abrasive cloths (like paper towels, which have tiny wood particles that can scratch glass) or rough sponges are a no-go. Even mild scratches might seem cosmetic, but over time, especially if they’re deep enough to reach the inner laminated layers, they can create weak points that compromise ballistic performance. I recommend using lint-free microfiber cloths—they’re soft enough not to scratch, and they pick up dirt without leaving streaks. For cleaners, avoid any ammonia-based products, vinegar, or abrasive cleaners. Ammonia can break down the PVB interlayer over time, causing it to degrade and lose its adhesive strength. That’s a big problem: if the interlayer stops bonding the glass layers together, a round could punch through gaps between layers instead of stopping in the composite. Instead, use a pH-neutral, non-abrasive glass cleaner, the same kind you’d use for high-end car windows or specialty glass displays. For stubborn grime, like dried bird droppings or construction residue, don’t scrape at it—dampen the microfiber cloth, let it sit on the spot for 30 seconds to soften the grime, then gently wipe. Scratching or scraping can damage the outer glass layer and transfer stress to the interlayer.
Next, inspection. You can’t just install EN 1063 glass and forget it—regular visual inspections are critical, and they should be done at least twice a year, or more often if the glass is in a high-traffic area, exposed to extreme weather, or near sources of potential impact (like loading docks or busy roads). What are you looking for? First, cracks or chips on the glass surface. Small chips (under 6mm, or ¼ inch) on the outer layer might seem trivial, but if they’re left unaddressed, they can spread, especially in extreme temperatures (hot days can expand glass, cold days contract it, putting stress on any existing damage). Even worse, chips near the edge of the glass panel can affect the adhesive that holds the glass in its frame, leading to gaps that a round could exploit. Next, check for any signs of delamination—this is a big one, and it’s often hard to spot. Delamination looks like a cloudy, bubbly, or hazy area in the laminated layers, usually around edges or where the glass has been exposed to moisture. Moisture is the enemy here: if water gets between the glass layers, it breaks down the interlayer’s bond, and over time, the glass can separate. If you notice delamination, that glass is compromised and needs to be replaced immediately. Also, check the frame and seal around the glass panel. The seals that keep moisture out are part of the EN 1063 system—if a seal is cracked or warped, moisture will get in, leading to delamination. That means inspections can’t be just looking at the glass itself; they have to include the surrounding frame, gaskets, and sealants. I always tell my customers to mark the date of inspections and note any issues, so they can track if damage is worsening over time.
Then, environmental protection steps that count as maintenance. EN 1063 glass is built to withstand a lot, but it’s not indestructible. If it’s installed in an area with extreme temperature swings, high humidity, or exposure to salt (like coastal locations), you need to take extra steps. Coastal environments, in particular, can accelerate seal degradation and interlayer breakdown, so I recommend rinsing the glass and frame quarterly with fresh water to remove salt residue. For areas with frequent wildfires, windblown debris can scratch or crack glass—if your location is at high risk, consider adding a temporary protective film (specifically designed for ballistic glass, not regular window film) during fire season to prevent impact damage. Also, avoid hanging heavy objects on or near the glass, or using it as a support for things like shelves. Even a small impact from a falling object (like a tool left on a ledge above the glass) can create stress points that weaken the laminate over time.
Now, what happens if you skip maintenance? I’ve seen this firsthand with customers who cut corners. A few years ago, I worked with a retail chain that had EN 1063 glass installed in their storefronts for protection against smash-and-grab theft. They cleaned it with regular ammonia-based window cleaner, and two years later, when they had a security test, we found that the PVB interlayer had degraded to the point that a BR1 round could penetrate the glass. The ammonia had broken down the interlayer’s molecular structure, turning the once-tough laminate into something that didn’t meet the EN 1063 standard. They had to replace all 12 storefront panels at a cost far higher than what they would have spent on proper cleaning supplies and regular inspections. Another common issue: a bank in a coastal city ignored seal inspections for three years. Moisture got in between the glass layers, causing delamination along the edges. When a robbery attempt happened, the round went through the delaminated area, and the glass shattered in a way that didn’t stop the attacker—luckily, no one was hurt, but the incident highlighted how maintenance isn’t just a cost, it’s a safety requirement.
Wait, but let’s be clear: not all maintenance is equal. There’s a difference between cosmetic maintenance (keeping the glass looking good for storefronts) and performance maintenance (preserving its ballistic rating). EN 1063 is a performance standard, so the goal of maintenance is to keep that performance intact, not just make the glass look clean. That’s why when we train our customers, we emphasize that any maintenance task that risks interlayer damage is a no-go. For example, some people use pressure washers to clean exterior glass—this is dangerous. High-pressure water can force its way through seal gaps, push water between the glass layers, and cause delamination. We strongly advise against pressure washing EN 1063 glass; if you need to clean an exterior panel, use a low-pressure spray (no more than 500 PSI) from a distance of at least 30cm, and avoid directing the spray at the edges or seals.
Also, what about repair vs. replacement? If you do find a small chip, can you repair it instead of replacing the panel? It depends. For EN 1063 glass, most standard glass repair kits (the kind used for car windshields) aren’t designed for laminated ballistic glass. The interlayer is thicker and more durable than auto glass’s interlayer, and the repair process can leave weak points that compromise ballistic performance. I always recommend that any chip larger than 6mm, or any chip within 10cm of the edge, be evaluated by a professional. If a chip is deep enough to reach the interlayer, replacement is almost always the only safe option. Trying to repair it can lead to failure during a ballistic event, which is a risk no business or property owner should take.
Let’s address a common myth: some people think because EN 1063 glass is tested to stop rounds, it can handle any wear and tear. That’s not true. The EN 1063 test is a single, controlled event—you shoot the glass once, from a specific distance, with a specific caliber. Real-world wear is cumulative: daily cleaning, temperature changes, moisture, small impacts from debris or tools, all add up. Maintenance is what preserves the glass’s ability to perform in a real-world threat, not just a test.
So, what does this mean for our customers who rely on EN 1063 glass? It means that a regular, low-effort maintenance routine is non-negotiable, but it’s not complicated. The steps are: clean with pH-neutral cleaner and microfiber cloths (no abrasives, no ammonia), inspect twice a year for chips, cracks, or delamination, check seals and frames for damage, and address any issues immediately by working with a professional. Skipping these steps doesn’t just void the warranty (most EN 1063 glass warranties require proper maintenance to stay valid)—it puts the people and property protected by the glass at risk.
At the end of the day, EN 1063 glass is only as good as its condition. A brand-new, properly installed panel will meet the standard, but without maintenance, that performance degrades over time. If you’re managing a facility with EN 1063 glass, or you’re looking to install it for the first time, don’t treat maintenance as an afterthought. It’s a critical part of ensuring the glass does its job when you need it most.

If you have questions about specific maintenance routines for your EN 1063 glazing system, or you’re ready to procure high-quality ballistic glass that meets and maintains the EN 1063 standard, reach out to our team to discuss your project needs.
Bulletproof Glass for Stanag 4569 Standard References
- European Committee for Standardization. (2019). EN 1063: Glass in building – Security glazing – Ballistic resistance.
- International Association of Chiefs of Police. (2021). Ballistic Glazing Maintenance Best Practices for Commercial and Residential Applications.
- Society of Glass and Ceramic Decorators. (2022). Care and Cleaning of Laminated Ballistic Glazing.
Shaoxing Transparent Armoring Materials Co., Ltd.